{"id":8824,"date":"2025-07-03T11:02:29","date_gmt":"2025-07-03T15:02:29","guid":{"rendered":"https:\/\/gm-techlinkfrench.com\/?p=8824"},"modified":"2025-10-03T11:12:49","modified_gmt":"2025-10-03T15:12:49","slug":"perte-de-climatisation-et-problemes-dair-chaud","status":"publish","type":"post","link":"https:\/\/gm-techlinkfrench.com\/?p=8824","title":{"rendered":"Perte de climatisation et probl\u00e8mes d&#8217;air chaud"},"content":{"rendered":"<p><span data-contrast=\"auto\">Il peut y avoir une perte de climatisation, un faible refroidissement ou de l&#8217;air chaud sortant des bouches d&#8217;air sur certains camions Silverado 1500 et Sierra 1500 2024-2025.\u00a0<\/span><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Ces conditions peuvent \u00eatre dues \u00e0 la chambre de dessiccateur du condenseur de climatiseur.\u00a0<\/span><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Rechercher des \u00e9raillures (Fig. 7, fl\u00e8ches rouges) \u00e0 l&#8217;int\u00e9rieur de la chambre de dessiccateur, ce qui peut causer une fuite lente du frigorig\u00e8ne au niveau du bouchon de r\u00e9cepteur\/dessiccateur.\u00a0<\/span><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-20209\" src=\"https:\/\/gm-techlink.com\/wp-content\/uploads\/2025\/08\/F07-des-1.jpg\" alt=\"\" width=\"740\" height=\"480\" \/><\/p>\n<p style=\"text-align: center;\"><b><span data-contrast=\"auto\">Fig. 7<\/span><\/b><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">V\u00e9rifier le bouchon compl\u00e8tement \u00e0 l&#8217;aide d&#8217;un d\u00e9tecteur de fuites de fluide frigorig\u00e8ne (d\u00e9tecteur \u00e9lectronique de fuites GE-50078<\/span> <span data-contrast=\"auto\">) ou d&#8217;une solution savonneuse pour identifier toute fuite. Remplacer le condenseur si une fuite est constat\u00e9e. (Fig. 8, condenseur (no 1) et radiateur (no 2) &#8211; (moteurs L84\/L87)) Se reporter \u00e0 Remplacement du compresseur de climatiseur dans les informations d&#8217;entretien appropri\u00e9es.\u00a0<\/span><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-20210\" src=\"https:\/\/gm-techlink.com\/wp-content\/uploads\/2025\/08\/F08-des-4.jpg\" alt=\"\" width=\"740\" height=\"480\" \/><\/p>\n<p style=\"text-align: center;\"><b><span data-contrast=\"auto\">Fig. 8<\/span><\/b><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Sur les v\u00e9hicules \u00e9quip\u00e9s du moteur 2,7 L (\u00e9quipement facultatif commun (RPO) L3B) ou du moteur diesel 3 L (RPO LZ0), d\u00e9poser le refroidisseur d&#8217;air de suralimentation, le condenseur, le moteur de ventilateur et le radiateur en un ensemble. (Fig. 9)<\/span><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-20211\" src=\"https:\/\/gm-techlink.com\/wp-content\/uploads\/2025\/08\/F09-des-2.jpg\" alt=\"\" width=\"740\" height=\"480\" \/><\/p>\n<p style=\"text-align: center;\"><b><span data-contrast=\"auto\">Fig. 9<\/span><\/b><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Sur les v\u00e9hicules \u00e9quip\u00e9s du moteur 5,3 L ou 6,2 L (\u00e9quipement facultatif commun (RPO) L84, L87), d\u00e9poser le condenseur, le moteur de ventilateur, le radiateur et le refroidisseur auxiliaire d&#8217;huile de bo\u00eete de vitesses, si le v\u00e9hicule en est \u00e9quip\u00e9, en un ensemble. (Fig. 10)<\/span><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p style=\"text-align: center;\"><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-20212\" src=\"https:\/\/gm-techlink.com\/wp-content\/uploads\/2025\/08\/F10-des-3.jpg\" alt=\"\" width=\"740\" height=\"480\" \/><\/p>\n<p style=\"text-align: center;\"><b><span data-contrast=\"auto\">Fig. 10<\/span><\/b><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Se reporter au bulletin n\u00b0 25-NA-170 pour plus de d\u00e9tails, y compris le code d&#8217;usine et le num\u00e9ro de pi\u00e8ce du condenseur.<\/span><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n<p><i><span data-contrast=\"auto\">Merci \u00e0 Dave MacGillis<\/span><\/i><span data-ccp-props=\"{&quot;335559737&quot;:720,&quot;335559739&quot;:120}\">\u00a0<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Il peut y avoir une perte de climatisation, un faible refroidissement ou de l&#8217;air chaud sortant des bouches d&#8217;air sur certains camions Silverado 1500 et Sierra 1500 2024-2025.\u00a0\u00a0 Ces conditions [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[80],"tags":[],"class_list":["post-8824","post","type-post","status-publish","format-standard","hentry","category-2025-july"],"_links":{"self":[{"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=\/wp\/v2\/posts\/8824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8824"}],"version-history":[{"count":1,"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=\/wp\/v2\/posts\/8824\/revisions"}],"predecessor-version":[{"id":8825,"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=\/wp\/v2\/posts\/8824\/revisions\/8825"}],"wp:attachment":[{"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8824"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=8824"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gm-techlinkfrench.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=8824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}